Select a System:

BWS003

Portable desktop spectrophotometer, 225 - 1000 nm diffuse reflectance/transmittance spectrophotometer system with built-in integrating sphere and high intensity pulse xenon light source assembly, back thinned CCD array based spectrometer, USB interface, Spectralon reference disk for reflection. Includes forced air cooling, BW Spec™ software for Windows® with "My Instrument" interface. Wavelength resolution is ~2,5 nm.

BWS004

Portable desktop spectrophotometer, 920 - 1700 nm diffuse reflectance/transmittance spectrophotometer system with built-in integrating sphere and high intensity, long life time light source assembly, InGaAs array based spectrometer, USB interface, Spectralon reference disk for reflection. Includes forced air cooling, BW Spec™ software for Windows® with "My Instrument" interface. Wavelength resolution is ~3,5 nm.

BWS005-05

Portable spectrophotometer, 400 - 2200 nm Broadband spectrometer system for transmission/absorption and reflection measurement applications with built-in high intensity 5 W, long lifetime lamp assembly, Si/Extended InGaAs array based detection systems, USB interface, Includes forced air cooling. Wavelength resolution is ~4 nm in 400 - 1100 nm range, and ~13 nm resolution from 1100 - 2200 nm.

BWS005-20

Portable spectrophotometer, 400 - 2200 nm Broadband spectrometer system for transmission/absorption and reflection measurement applications with built-in high intensity 20 W, long lifetime lamp assembly, Si/Extended InGaAs array based detection systems, USB interface, Includes forced air cooling. Wavelength resolution is ~4 nm in 400 - 1100 nm range, and ~13 nm resolution from 1100 - 2200 nm.

BWS015-05

Portable spectrophotometer, 350 - 1700 nm Broadband spectrometer system for transmission/absorption or reflection with built-in high intensity, 5 W, long lifetime lamp assembly, Si/InGaAs array based detection systems, USB interface, Includes forced air cooling. Wavelength resolution is ~4 nm.

BWS015-20

Portable spectrophotometer, 350 - 1700 nm Broadband spectrometer system for transmission/absorption or reflection with built-in high intensity, 20W, long lifetime lamp assembly, Si/InGaAs array based detection systems, USB interface, Includes forced air cooling. Wavelength resolution is ~4 nm.

BWS025-05

Portable spectrophotometer, 1100 - 2200 nm Broadband spectrometer system for transmission/absorption and reflection measurement applications with built-in high intensity 5 W, long lifetime lamp assembly, Extended InGaAs array based detection systems, USB interface, Includes forced air cooling. Wavelength resolution is ~13 nm resolution from 1100 - 2200 nm.

BWS025-20

Portable spectrophotometer, 1100 - 2200 nm Broadband spectrometer system for transmission/absorption and reflection measurement applications with built-in high intensity 20 W, long lifetime lamp assembly, Extended InGaAs array based detection systems, USB interface, Includes forced air cooling. Wavelength resolution is ~13 nm resolution from 1100 - 2200 nm.

BWS035-05

Portable spectrophotometer, 900 - 1700 nm Broadband spectrometer system for transmission/absorption or reflection with built-in high intensity, 5 W, long lifetime lamp assembly, InGaAs array based detection systems, USB interface, Includes forced air cooling. Wavelength resolution is ~4 nm.

BWS035-20

Portable spectrophotometer, 900 - 1700 nm Broadband spectrometer system for transmission/absorption or reflection with built-in high intensity, 20 W, long lifetime lamp assembly, InGaAs array based detection systems, USB interface, Includes forced air cooling. Wavelength resolution is ~4 nm.

BTT111

Portable spectrophotometer, 190 - 1050 Miniature Array Spectrometer for the measurement of transmission, absorption, or reflection of liquids. Uses deuterium & tungsten halogen lamps. Optical resolution 1.5 nm.

Select a System:

BTF113

MiniFluo - miniature TE cooled fluorometer system with pulsed xenon lamp excitation source. The excitation wavelength range is selectable via a filter set from 240 - 780 nm. The emission wavelength range is selectable via filter from 280 - 780 nm. The spectral resolution is 8 - 10 nm (FWHM). Detector is 2048 element linear CCD array, TE cooled. Windows based operating software included, USB 1.1/2.0 User must select filter set for excitation/emission.

Select a System:

BSR112E-VIS

Miniature spectral irradiance meter with integrated transmissive cosine corrected input optics, wavelength range 380-750 nm with spectral resolution of ~2.8 nm FWHM, built-in 16 bit digitizer, USB 2.0/1.1 interface. USB cable and NIST traceable Irradiance calibration are included, CIE127 adapter for LED intensity measurement is not included.

BSR112E-VIS/NIR

Miniature spectral irradiance meter with integrated transmissive cosine corrected input optics, wavelength range 350-1050 nm with spectral resolution of ~3.9 nm FWHM, built-in 16 bit digitizer, USB 2.0/1.1 interface. USB cable and NIST traceable Irradiance calibration are included, CIE127 adapter for LED intensity measurement is not included.