Bookmark and Share
 Home  Contact Us  About Us  

COMPARE PRODUCTS
 Systems Next 
 
BWS003
Principle
  • Single beam integrating sphere, light source stabilized, UV/Vis/Short Wave NIR transmittance/absorbance/reflectance Spectrophotometer with USB interface, operated by personal computer with associated programs installed.
Optical System
  • Crossed Czerny-Turner spectrograph optical layout, high throughput optics with UV-NIR sensitivity enhancement sensor array detection.
Integration Sphere
  • Default 4” Labsphere spectralon material based integrating sphere
Port Ratio
  • 5.0% : 4” integration sphere
Detector
  • UV enhanced TE cooled and temperature stabilized high dynamic range back-thinned 1024 pixel CCD
Detector Temperature
  • 0 °C
Temperature stability
  • Better than ± 0.2 °C
Sampling
  • Built-in sample holders for reflectance and transmittance/absorbance
Source
  • 5 W Pre-aligned Xenon Flash Light, 109 Flash Life-time
Wavelength Range
  • 250 nm–1000 nm or 200-950 nm
Pixel Resolution
  • 0.7 nm
Wavelength Accuracy
  • 1 pixel
Wavelength Reproducibility
  • 1 pixel
Stray light
  • 0.0007 %T at 370 nm
Photometric repeatability
  • 0.005 A
Photometric Range
  • 5 A
Measuring Speed
  • 26 ms to 65,535 ms
Sample Holder
  • Standard 10 mm cuvette for liquid and powder measurement
Sample Holder
  • Standard 10 mm cuvette for liquid and powder measurement
(Transmittance)
  • 1 mm – 10 mm thickness sheet sample allowed
Sample Holder
  • 25 mm port diameter with frame reducer options
(Reflectance)
  • FIP Fiber coupled stainless steel absorption immersion probe.
In-process measurement probe
  • Absorption length 5mm, 10mm and 20mm selectable.
Computer interface
  • USB 2.0/1.1
Maximum data throughout
  • 20 spectra / second
Software Interface
  • My Instrument OCX Control for interfacing to GRAMS AI spectral analytic software
Instrument Dimension
  • 17.7 x 13.2 x 8.5 inches [449 x 333 x 216 mm]
Instrument Weight
  • 15 lbs [6.75 kg]
Power
  • 100 VAC–240 VAC, 50/60 Hz; 40 VA
 
 
BWS004
Principle
  • Single beam integrating sphere, light source stabilized, NIR transmittance/absorbance/reflectance Spectrophotometer with USB interface, operated by personal computer with associated programs installed.
Optical System
  • Crossed Czerny-Turner spectrograph optical layout, high throughput optics with NIR sensitivity enhancement sensor array detection.
Integration Sphere
  • Default 4” Spectralon material based integrating sphere
Port Ratio
  • 5.0% : 4” integration sphere
Detector
  • TE cooled and temperature stabilized high dynamic range 512 pixel InGaAs detector array for 920-1700 nm
Detector Temperature
  • 0 °C
Temperature stability
  • Better than ± 0.2 °C
Sampling
  • Lens and Fiber coupled
Source
  • 30 W Pre-aligned tungsten
Wavelength Range
  • 920 nm–1700 nm
Pixel Resolution
  • 4 nm for 920-1700 nm
Wavelength Accuracy
  • 1 pixel
Wavelength Reproducibility
  • 1 pixel
Stray light
  • 0.004 at 1420 nm
Photometric repeatability
  • 0.01 A
Photometric Range
  • 5 A
Measuring Speed
  • 1 ms to 65,535 ms
Sample Holder
  • Standard 10 mm cuvette for liquid and powder measurement
Sample Holder
  • Standard 10 mm cuvette for liquid and powder measurement
(Transmittance)
  • 1 mm – 10 mm thickness sheet sample allowed
Sample Holder
  • 25 mm port diameter with frame reducer options
(Reflectance)
  • FIP Fiber coupled stainless steel absorption immersion probe.
In-process measurement probe
  • Absorption length 5mm, 10mm and 20mm selectable.
Computer interface
  • USB 2.0/1.1
Maximum data throughout
  • 100 spectra / second
Software Interface
  • My Instrument OCX Control for interfacing to GRAMS AI spectral analytic software
Instrument Dimension
  • 17.7 x 13.2 x 8.5 inches [449 x 333 x 216 mm]
Instrument Weight
  • 15 lbs [6.75 kg]
Power
  • 100 VAC–240 VAC, 50/60 Hz; 60 VA
 
 
 
  © 2009 B&W Tek, Inc. All rights reserved.
Specifications are subject to change without notice.